Technical Insights

技術記事

モータ動力計ベンチ、負荷装置、eドライブ量産検査に関するLANDIエンジニアリングチームの選定ガイドと試験手法。

2026-08-18

How to choose a motor test bench: six decisions that matter

Speed, torque, accuracy, cooling, software and acceptance criteria — the six specifications that decide whether a motor dynamometer bench will actually do the job, and what each one costs you if you get it wrong.

詳しく見る
2026-08-25

Resistive vs RLC load banks: what genset and UPS testing actually needs

A purely resistive load only proves half of what a genset can do. This article explains the role of power factor, inductive and capacitive loading in real commissioning tests, and how to choose between containerised and rack-mounted load banks.

詳しく見る
2026-09-01

EOL testing for EV 3-in-1 drive units: cycle time, judgement and traceability

An e-drive assembly has to be performance-checked, NVH-judged and archived in about a minute. This article covers station layout, which tests to keep, and how pass/fail thresholds are set in practice.

詳しく見る
2026-09-02

What is a load bank? Principle, types and typical uses

A load bank is a controllable artificial load used to prove that gensets, UPS systems and power plants perform at real power. This article explains how one works, the resistive, inductive and capacitive types, and where each is used.

詳しく見る
2026-09-03

How to size a load bank: four calculations that decide the specification

From rated capacity and power factor to voltage class, cooling and site conditions — the four calculations behind a load bank specification, and the mistakes that come up most often.

詳しく見る
2026-09-04

Dynamometer types compared: eddy current, AC and DC

How eddy-current, AC and DC dynamometers differ in dynamic response, energy recovery and cost — and which test job each one suits.

詳しく見る
2026-09-05

Where the uncertainty in a motor efficiency measurement comes from

Efficiency error is rarely set by the sensor datasheet. This article breaks down how torque, speed, electrical power and sampling synchronisation combine, and what actually reduces the error.

詳しく見る
2026-09-06

What an anti-islanding test really measures: IEEE 1547 and IEC 62116

Why anti-islanding testing needs a precisely tuned RLC resonant load, what the quality factor Qf means, and where these tests most often go wrong.

詳しく見る
2026-09-07

Wet stacking in standby generators, and why you run a load bank

Standby diesel sets running lightly for years accumulate unburnt fuel, carbon and lost power. This article covers the cause, how to recognise it, and how to run the periodic full-load exercise.

詳しく見る
2026-09-07

Installing and calibrating a torque transducer: the details that move the numbers

Alignment, coupling choice, range matching and calibration interval usually affect a torque measurement more than the transducer's accuracy class does.

詳しく見る